Question 1: Do any of you place an alarm or upper limit on the operating pressure drop (dP) through a hydrotreater reactor circuit (preheat exchangers to High Pressure Separator)? If yes, what is the basis for the maximum dP?

One of our refineries has developed limits for pressure drop through the reactor circuit. The maximum allowable pressure drop is determined by the difference between the upstream reactor or heat exchanger design pressure and the set pressure of the relief valve on the high-pressure separator. The purpose of the alarm is to ensure that the upstream vessel’s design pressure will not be exceeded before the pressure at the downstream relief valve reaches the set pressure.