Skip to main content
Home Home

Main navigation

  • Industries
    • Products
    • Operations
    • Performance
    • People
    • Contributions

    Industries

    We represent the makers of the fuels that keep Americans moving and the petrochemicals that are the essential building blocks for modern life. Our industries make life better, safer, more productive and — most of all — possible.

  • Issues
    • Fuels & Vehicles
    • Environment
    • Petrochemicals
    • Safety & Health
    • Security
    • Tax & Trade
    • Transportation & Infrastructure
    • Regulatory Reform

    Issues

    We advocate for public policies that promote growth and investment in the refining and petrochemical manufacturing industries to help drive our economy, add jobs, increase energy security and remain competitive in a global economy.

  • Events
    • My Meetings
    • Speaker Guidelines
    • Meeting FAQ
    • Sponsorship
    • Upcoming Events

    View AFPM Calendar of Events

    We offer a portfolio of first-in-class events that educate our members and other stakeholders on critical technical and advocacy issues, supporting the safety, security and success of the fuel and petrochemical industries.

     

  • Newsroom
  • Search
    Enter a list of keywords and press Enter to submit your search query.

Utility Menu (Mobile)

  • About Us
  • Membership
  • Data & Reports
  • Safety Programs

User account menu

  • My AFPM

Social Media Menu - Header

  • Icon
  • Icon
  • Icon
  • Icon
  • Icon

Utility Menu

  • About Us
    • About AFPM
    • Our History
    • Careers
    • Contact Us
  • Membership
    • AFPM Membership
    • Member Directory
  • Data & Reports
    • Data & Statistics
    • Publications
    • Technical Papers
    • Annual Report
    • Sustainability Report
  • Safety Programs
    • Safety Portal
    • Advancing Process Safety Programs
    • Occupational Safety Programs
    • Safety Statistics Programs
    • Safety Awards & Recognition
Enter a list of keywords and press Enter to submit your search query.

Q&A

Find the answer to your technical question in AFPM's extensive Q&A database.

wave
  1. Data & Reports
  2. Technical Papers
  3. Q&A

Q&A

These digital transcripts are meant to share information on process safety practices in order to help improve process safety performance and awareness throughout industry. The goal is to capture and share knowledge that could be used by other companies or sites when developing new process safety practices or improving existing ones. The documents being shared have been used by an industry member, but this does not mean it should be used or that it will produce similar results at any other site. Rather, it is an option to consider when implementing or adjusting programs and practices at a site. ​

BY THEMSELVES, THESE DIGITAL TRANSCRIPTS ARE NOT STANDARDS OR RECOMMENDED PRACTICES. THEY ARE NOT INTENDED TO REPLACE SOUND ENGINEERING JUDGMENT. THEY DO NOT PRECLUDE THE USE OF ALTERNATIVE METHODS THAT COMPLY WITH LEGAL REQUIREMENTS. A SUBJECT MATTER EXPERT SHOULD BE CONSULTED PRIOR TO DETERMINING WHETHER A PRACTICE CAN BE USED IN ANY SPECIFIC SITUATION. 

​

Process

  • (-) FCC
    • Alkylation
    • Environmental
    • Catalysts
  • Gasoline Processing
    • Safety
    • Gasoline Processing
    • Desalting
    • Reforming
    • Catalytic Reforming
    • Isomerization
    • Naphtha Hydrotreating
    • Aromatics
    • HF Alkylation (HF Alky)
    • Blending
    • Plant Services
  • Crude/Coking
    • (-) Corrosion
    • Process
    • Operations
    • Mechanical
    • Coker
    • Reliability
    • Crude Quality
    • Vacuum Tower
    • Distillation
    • CAT POLY Units (CAT Poly)
    • Desalting
    • Naphtha Hydrotreating
    • Safety
  • Hydroprocessing
    • Catalysts
    • Resid Hydrocracking
    • Hydrocracking Catalyst
    • Feed Quality
    • Fouling
    • Naphtha Hydrotreating
    • ULSD

Submitter

  • Operator
  • Licensor
  • Vendor
  • Consultant

Year QA

  • 2018
  • 2017
  • 2016
  • 2015
  • 2014
  • 2013
  • 2012
  • 2011
  • 2010
Search Filters

Process

  • (-) FCC
    • Alkylation
    • Environmental
    • Catalysts
  • Gasoline Processing
    • Safety
    • Gasoline Processing
    • Desalting
    • Reforming
    • Catalytic Reforming
    • Isomerization
    • Naphtha Hydrotreating
    • Aromatics
    • HF Alkylation (HF Alky)
    • Blending
    • Plant Services
  • Crude/Coking
    • (-) Corrosion
    • Process
    • Operations
    • Mechanical
    • Coker
    • Reliability
    • Crude Quality
    • Vacuum Tower
    • Distillation
    • CAT POLY Units (CAT Poly)
    • Desalting
    • Naphtha Hydrotreating
    • Safety
  • Hydroprocessing
    • Catalysts
    • Resid Hydrocracking
    • Hydrocracking Catalyst
    • Feed Quality
    • Fouling
    • Naphtha Hydrotreating
    • ULSD

Submitter

  • Operator
  • Licensor
  • Vendor
  • Consultant

Year QA

  • 2018
  • 2017
  • 2016
  • 2015
  • 2014
  • 2013
  • 2012
  • 2011
  • 2010
Filters

Question 6: Some CO and waste heat boilers operate with bypass stacks separated by seal pots or isolation valves. Maintenance of these seal systems can be expensive and these seal systems can be sources of poor reliability. What design upgrades and operating practices have enabled you to eliminate these bypass systems?

Holly Refining continues to use bypass stacks with diversion valves at both of our refineries. Those stacks and diversion valves are allowed by permit and we use them during startup/shutdown manning upset conditions. Both our Operations and Maintenance groups are assigned weekly preventative maintenance tasks to ensure operability when we do have to throw these valves.
Read more

Question 7: Is your company either considering, or actually implementing, FCC projects that include reduced CO2 emissions (greenhouse gas reduction-GHGR) as an offset/credit?

We do not have any current FCC projects that plan on utilizing some form of CO2 offset or credit in the emissions analysis. ConocoPhillips has performed a limited modeling study to evaluate the effect of operational changes on CO2 emissions from the FCC. Also, the study indicated that there is very little you can do to reduce overall emissions without also overall significantly reducing unit throughput or conversion.
Read more

Question 10: What is your recent experience regarding the maximum level of equilibrium catalyst metals (Ni, V, Na, Fe, Ca) in FCC units processing residual feedstocks? Have there been any recent improvements in vanadium passivation technologies? At nickel levels approaching 10,000 ppm, have you experienced increased catalyst deactivation as evidenced by lower equilibrium zeolite surface area?

Here we see data regarding one of our FCCUs that operates at e-cat nickel levels exceeding 10,000 ppm. We observe that the MAT generally remains within the same range until high e-cat nickel concentrations are approached.
Read more

(2012) Question 76: The check valve on the air blower discharge line is designed to protect the blower from hot catalyst that backs into it when the blower fails. What type of valve is used in this service, where is it located, and what is done to ensure that it closes properly?

UOP specifies two special check valves in the blower discharge line. The first special check valve is installed a minimum distance from the blower discharge downstream in the snort (or anti-surge) valve in a horizontal pipe run.
Read more

(2012) Question 77: For our emergency interlock system, we employ two-out-of-three voting systems for slide valve differential pressure transmitters. We use dedicated transmitter taps for each transmitter, but we get inconsistent readings. What can we do, regarding design and maintenance, to ensure that these transmitters read more consistently? What should we do if we are unable to achieve consistent readings?

To obtain a more consistent reading, plant personnel should examine three phases: the transmitter, its physical location, and its instrument gas system. As for the transmitter, the technician should analyze it to ensure that it is within the accuracy specified by the manufacturer.
Read more

(2012) Question 78: What inputs or trips are typically included in FCC flue gas expanders and CO (carbon monoxide) boilers' safety interlock systems? Are there any governing standards [(e.g., API and NFPA (National Fire Protection Association)] that apply?

I would like to address this question as two different parts, beginning with the flue gas expanders. BP has three flue gas expanders in its system. These expanders are all set up with slightly different configurations. We have one FCCU flue gas expander that is directly coupled to the main air blower.
Read more

Question 79: What tools are being used to monitor FCC performance? What are the key performance indicators and expectations?

These are two broad categories for the use of these indicators. The first category is capacity utilization and yield performance, which covers process performance, operating constraints, and optimal use of any inherent design margins.
Read more

(2012) Question 80: We are considering severe hydrotreating of our FCC feed. What yield shifts or unusual operating problems might we expect? What can be done to address these issues?

Processing Hydrotreated Feed: First of all, let’s define what ‘severely’ hydrotreated feed means. One unit in our system hydrotreats the feed down to 50 ppm sulfur and 50 ppm nitrogen, so you can see that processing that type of feedstock has tremendous yield benefits.
Read more

(2012) Question 81: Is there experience with continuous torch oil and/or air preheater firing; and if so, for what reasons? What are the demonstrated effects from doing either of these processes?

We do not have much experience with continuous torch oil firing. We do have one unit that fires torch oil if the bed temperature drops below 1250ºF.
Read more

(2012) Question 82: Do you have any experience with the recycle of C4/C5 streams from the FCC gas plant back to the FCC? If so, what was your motivation? What is the system configuration, and what are the key operating parameters?

We have some experience recycling BBs (butane-butylenes) from the gas plant back to the FCC reactor, and even some C5s. I will start by saying that this is a very unusual operation.
Read more

Pagination

  • First page
  • Previous page ‹‹
  • …
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • Current page 42
  • Page 43
  • Page 44
  • Page 45
  • Next page ››
  • Last page

Data & Reports

  • Data & Statistics
  • Publications
  • Technical Papers
  • Annual Report
  • Sustainability Report

Stay in the Know

Subscribe to our monthly industry insights newsletter.

Footer menu (first)

  • My AFPM
  • Events
  • Safety Portal
  • Petrochemical Portal

Footer menu (second)

  • Contact Us
  • Privacy Policy
  • Legal

Connect with Us

  • Icon
  • Icon
  • Icon
  • Icon
  • Icon

© 2025 AFPM. All rights reserved 
American Fuel & Petrochemical Manufacturers
1800 M Street, NW Suite 900 North
Washington, DC 20036

Back to Top